LABORATORY FUME SCRUBBING

Fume cupboard scrubbers for laboratory acid fume

Compact packed-bed scrubbers for one to four fume cupboards, sized to fit integral to your fume hood or in a limited space plant room. Built for the HF, HCl and nitric acid fume that labs actually produce.


✓Serves one to four fume cupboards from one unit
✓Fan sized so your cupboards keep their face velocity
✓Fits an existing plant room or roof

​Not ready to quote? Download the fume cupboard scrubber guide

Request a quote

Four fields to start. A process engineer will reply within 4 working hours to talk through your lab.

Add lab details for a faster quote (optional)

Response time typically <4 Hours

UKCA and CE marked Polypropylene and PVDF For 1 to 4 fume cupboards Designed and built in the UK Supplying UK and Europe
The duty

Small airflows, aggressive acids

Laboratory extract is low in volume but high in hazard. HF, HCl and nitric digestions put corrosive fume straight into the duct, and on many sites the stack sits close to air intakes, windows and neighbouring buildings. Whether you call it a laboratory scrubber or a lab scrubber, it has to clean that fume without upsetting the extract your cupboards rely on.

Teaching and research

University and research labs

Many users, many methods and changing chemistry from one year to the next.

In the extract: HCl, nitric and HF fume from digestions and wet chemistry

What we fit: A compact packed-bed scrubber shared by compatible fume cupboards

Analytical and QC

Analytical and testing labs

Routine acid digestions for metals analysis and sample preparation, run every day.

In the extract: Nitric and HCl fume, with HF for silicate samples

What we fit: Caustic packed bed with automatic dosing and alarms

Specialist

Materials and semiconductor R&D

Specialist methods where one acid dominates or a stream must be kept apart.

In the extract: HF, perchloric or mixed acid streams

What we fit: A dedicated scrubber per stream, or a wash-down system for perchloric

Laboratory acids our fume cupboard scrubbers treat

AcidTypical lab useHow we scrub it
Hydrochloric (HCl)Digestions, cleaning, general wet chemistryCaustic or water packed bed
Hydrofluoric (HF)Silicate digestions, etching, materials researchCaustic packed bed in polypropylene or PVDF, nothing glass in the wetted path
Nitric acidDigestions, metals analysis, ICP sample preparationCaustic packed bed; oxidising stage only where NOx is significant
Sulphuric acidDigestions and heated workMist eliminator with the packed bed
Perchloric acidSpecialist digestionsDedicated wash-down fume cupboard and extract, never shared

Not on the list? Send us the methods and chemicals used in the fume cupboards and we will tell you whether a scrubber is the right answer.

Why a Caldera fume cupboard scrubber

Built around the lab you already have

Fits your plant room

Compact packed-bed units for one to four fume cupboards, sized to fit an existing plant room or roof rather than a new building.

Keeps your face velocity

We size the extract fan for the scrubber pressure drop, so your fume cupboards keep the face velocity they were tested to.

Built and wet-tested in house

Polypropylene or PVDF, fabricated by our own team and run wet in our factory before dispatch, with dosing and alarms to your BMS.

How a fume cupboard scrubber goes together

From fume cupboard to clean discharge

The train we supply most often behind one to four fume cupboards. Each unit is sized to your cupboards and your ductwork.

INFume cupboard extractFrom one to four cupboards
01Packed bedCounter-current contact absorbs the acid gas
02Sump and dosingRecirculation pump, level control and pH dosing
03Mist eliminatorStops liquor and acid mist carry-over
04Extract fanSized for the scrubber, holds face velocity
OUTClean dischargeAway from intakes and windows

Materials: polypropylene vessels and packing as standard, PVDF where HF or temperature needs it.

Controls: pH dosing to setpoint, liquor flow and level interlocks, alarms to your BMS.

Honest scope: perchloric acid never shares a scrubber. It needs a dedicated wash-down fume cupboard and extract.

For estates and facilities teams

Fits your building and your maintenance plan

A scrubber changes the extract system your fume cupboards depend on. We design it as part of that system, not as a box bolted on at the end.

Fume cupboards are tested to BS EN 14175, and their extract counts as local exhaust ventilation, which COSHH requires to be thoroughly examined at least every 14 months. We give you the data for both: fan duty, pressure drop and commissioning readings.

What estates teams get
  • A unit sized for the plant room or roof you have
  • Fan duty that keeps tested face velocities
  • Dosing and alarms through your BMS
  • A clear service routine and reagent use on the datasheet
Specification

Fume cupboard scrubber specifications

Indicative ranges for our fume cupboard scrubbers. Your figures are calculated against your duty and issued on a datasheet before anything is built.

Related: packed tower scrubbers, acid fume scrubbers and how a wet scrubber works.

Compact fume cupboard scrubbers
Duty range200 – 3,000 m³/h (typically one to four cupboards)
ConfigurationVertical counter-current packed tower, integral sump
Body materialsPolypropylene as standard; PVDF or GRP where the duty needs it
PackingRandom polypropylene, 25–50 mm, depth set by duty
Scrubbing liquorWater, dilute sodium hydroxide, or dilute acid for alkaline gases
Removal efficiency95%+ single stage on soluble acid gases; 99%+ two-stage
Pressure dropTypically 300 – 800 Pa across the wetted bed
Mist eliminationChevron or mesh pad, removable for cleaning
InstrumentationpH, sump level, liquor flow proving, differential pressure
InterfacesVolt-free alarm contacts and Modbus RTU/TCP to BMS
What happens when you ask

From enquiry to a commissioned fume cupboard scrubber

01

Tell us about the lab

Four fields, plus the number of fume cupboards and the methods they run, if you have them.

02

Engineer reply in 4 hours

A process engineer, not a salesperson, comes back within 4 working hours and arranges a site survey if useful.

03

Sizing and quotation

Datasheet, general arrangement and price, in 10 working days.

04

Build, test, commission

Fabricated and wet-tested in the UK, installed and commissioned around your lab timetable.

Free technical guide

When does a fume cupboard need a scrubber? A guide for labs and estates

Which acids and volumes need scrubbing, how a scrubber affects face velocity and fan duty, where it can go, and what to plan for maintenance.

Thanks. Your guide is ready to download.

Download the PDF guide

Questions labs ask us

Will a scrubber reduce our face velocity?

Not if the fan is sized for it. The scrubber adds pressure drop to the extract, so we size the fan for the whole system and check face velocities at commissioning.

Can one fume cupboard scrubber serve several cupboards?

Yes, one to four cupboards per unit where the acids are compatible. Streams that must stay apart get their own scrubber.

What about perchloric acid?

Perchloric work needs a dedicated wash-down fume cupboard and extract. It is never connected to a shared scrubber, because perchlorate deposits can be shock-sensitive.

Where does the scrubber go?

Usually in an existing plant room or on the roof, close to the fan. We survey the route and the space before we quote.

Do you supply outside the UK?

Yes, across the UK and Europe. Equipment is UKCA and CE marked.

Tell us what your fume cupboards are used for

Send the acids, the number of cupboards and where a scrubber could go. We will tell you what will work, and what will not, before anyone talks about price.